Technical overview
What you are specifying.
- AC control
- Infrared power, mode, setpoint, and fan commands for compatible AC units
- Built-in sensing
- Temperature −20 to 60°C; relative humidity 0–100% RH
- Temperature accuracy
- ±0.5°C from 0 to 60°C; ±1°C from −20 to 0°C
- Humidity accuracy
- ±3% RH from 40–85% RH; ±5% RH outside that band
- Wireless
- LoRaWAN Class B / Class C; region and network support confirmed for each site
- Configuration
- Milesight ToolBox via Bluetooth; supported remote downlinks
- External interfaces
- One NTC temperature input, one current-transformer input, one IR-emitter input
- Power
- 5V DC / 1A via USB-C; optional three-AA alkaline battery compartment (0–40°C battery operation)
- Enclosure
- IP40; 96 × 48 × 26 mm; indoor, non-condensing deployment
- Local functions
- Weekly schedules, temperature limits, threshold alarms, and elapsed-day filter reminders
Choose the accessories.
- NTC probe: room or outlet-air temperature. Concealed mounting requires this probe and an external IR emitter.
- Current transformer: rough current and running feedback. USB power is recommended for CT deployments.
- WT401 thermostat: local room interaction over Bluetooth.
- Battery compartment: optional three-AA power for sites without a nearby supply. Batteries are separate; battery operation is rated for 0–40°C.
Confirm the fit.
Commission the actual AC and remote combination. A controller acknowledgement does not confirm the AC acted. Validate current and temperature response; current feedback strengthens running checks. The controller estimates energy from runtime and configured power. Add a dedicated energy meter when measured kWh is required.
One NTC input measures one point. Simultaneous supply-and-return temperature measurements need additional sensors. CT installation requires qualified electrical personnel.